Publication Date: |
|
Last Update: |
|
Current Version: | V1.2 |
CVSS v3.1 Base Score: | 6.2 |
Affected Product and Versions | Remediation |
---|---|
|
Currently no fix is planned
|
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.
This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.
CVSS v3.1 Base Score | 6.2 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C |
CWE | CWE-693: Protection Mechanism Failure |
V1.0 (2023-06-13): | Publication Date |
V1.1 (2023-12-12): | Added Totally Integrated Automation Portal (TIA Portal) V19 as affected product |
V1.2 (2024-12-10): | No fix planned for Totally Integrated Automation Portal (TIA Portal) V19; Added Totally Integrated Automation Portal (TIA Portal) V20 as affected product |