Publication Date: |
|
Last Update: |
|
Current Version: | V1.0 |
CVSS v3.1 Base Score: | 7.8 |
CVSS v4.0 Base Score: | 8.5 |
Affected Product and Versions | Remediation |
---|---|
All versions < V3.4.0 affected by CVE-2024-47783 |
Update to V3.4.0 or later version
|
Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
The affected application improperly assigns file permissions to installation folders.
This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.
CVSS v3.1 Base Score | 7.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
CVSS v4.0 Base Score | 8.5 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CWE | CWE-732: Incorrect Permission Assignment for Critical Resource |
V1.0 (2024-11-12): | Publication Date |