| Publication Date: |
|
| Last Update: |
|
| Current Version: | V1.1 |
| CVSS v3.1 Base Score: | 8.1 |
| Affected Product and Versions | Remediation |
|---|---|
|
All versions with Fortinet NGFW |
Update Fortigate NGFW to V7.6.7 or later following the secure update recommendation procedure. Contact customer support to receive detailed information
|
Product-specific remediations or mitigations can be found in the section
Known Affected Products.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
| CVSS v3.1 Base Score | 6.1 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
| CWE | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') |
| CVSS v3.1 Base Score | 5.5 |
| CVSS v3.1 Vector | CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H |
| CWE | CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') |
| CVSS v3.1 Base Score | 5.6 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L |
| CWE | CWE-121: Stack-based Buffer Overflow |
| CVSS v3.1 Base Score | 5.3 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L |
| CWE | CWE-770: Allocation of Resources Without Limits or Throttling |
| CVSS v3.1 Base Score | 8.1 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CWE | CWE-297: Improper Validation of Certificate with Host Mismatch |
Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications. Fortinet provides a public RSS feed for their security alerts to which customers can also subscribe [1].
[1] https://filestore.fortinet.com/fortiguard/rss/ir.xml
| V1.0 (2026-08-11): | Publication Date |
| V1.1 (2026-10-13): | Added CVE-2026-71408, CVE-2026-71407 and CVE-2026-84393 |