Publication Date:
Last Update:
Current Version: V1.1
CVSS v3.1 Base Score: 8.1
Un-/Collapse All
Affected Product and Versions Remediation

All versions with Fortinet NGFW
affected by all CVEs
Update Fortigate NGFW to V7.6.7 or later following the secure update recommendation procedure. Contact customer support to receive detailed information

Product-specific remediations or mitigations can be found in the section Known Affected Products.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 6.1
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
CWE CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVSS v3.1 Base Score 5.5
CVSS v3.1 Vector CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
CWE CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVSS v3.1 Base Score 5.6
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L
CWE CWE-121: Stack-based Buffer Overflow
CVSS v3.1 Base Score 5.3
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
CWE CWE-770: Allocation of Resources Without Limits or Throttling
CVSS v3.1 Base Score 8.1
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE CWE-297: Improper Validation of Certificate with Host Mismatch

Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications. Fortinet provides a public RSS feed for their security alerts to which customers can also subscribe [1].

[1] https://filestore.fortinet.com/fortiguard/rss/ir.xml

https://www.siemens.com/cert/advisories
V1.0 (2026-08-11): Publication Date
V1.1 (2026-10-13): Added CVE-2026-71408, CVE-2026-71407 and CVE-2026-84393