Publication Date: |
|
Last Update: |
|
Current Version: | V1.1 |
CVSS v3.1 Base Score: | 7.8 |
Affected Product and Versions | Remediation |
---|---|
All versions < V2.0 affected by all CVEs |
Update to V2.0 or later version
|
Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
The affected application assigns improper access rights to specific folders containing executable files and libraries.
This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
CVSS v3.1 Base Score | 7.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-732: Incorrect Permission Assignment for Critical Resource |
CVSS v3.1 Base Score | 4.7 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C |
CWE | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') |
V1.0 (2023-10-10): | Publication Date |
V1.1 (2024-07-09): | Added acknowledgement for CVE-2022-30527 |