Publication Date:
Last Update:
Current Version: V1.1
CVSS v3.1 Base Score: 5.3
CVSS v4.0 Base Score: 6.9
Un-/Collapse All
Affected Product and Versions Remediation
Expand children
Update to V3.1.2 or later version
Disable HTTP (port 80/tcp) and provide web service access through HTTPS (port 443/tcp) only; the vulnerability is considered as only exploitable via HTTP

All versions >= V30.1.0 < V31.1.4
affected by CVE-2023-37482
Update to V31.1.4 or later version
Disable HTTP (port 80/tcp) and provide web service access through HTTPS (port 443/tcp) only; the vulnerability is considered as only exploitable via HTTP
Expand children

All versions >= V30.1.0
affected by CVE-2023-37482
Currently no fix is available
Disable HTTP (port 80/tcp) and provide web service access through HTTPS (port 443/tcp) only; the vulnerability is considered as only exploitable via HTTP

All versions >= V6.0 < V7.0
affected by CVE-2023-37482
Update to V7.0 or later version
Disable HTTP (port 80/tcp) and provide web service access through HTTPS (port 443/tcp) only; the vulnerability is considered as only exploitable via HTTP

Product-specific remediations or mitigations can be found in the section Affected Products and Solution.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 5.3
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS v4.0 Base Score 6.9
CVSS v4.0 Vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
CWE CWE-203: Observable Discrepancy

  • David Henrique Estevam de Andrade for reporting the vulnerability

Note that the webserver in above-listed products is deactivated by default; when activated, by default it provides HTTPS (port 443/tcp) only, but not HTTP (port 80/tcp).

https://www.siemens.com/cert/advisories
V1.0 (2025-02-11): Publication Date
V1.1 (2025-03-11): Added fix for SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)