Publication Date: 2022-03-08
Last Update: 2022-03-08
Current Version: V1.0
CVSS v3.1 Base Score: 8.2

Affected Product and Versions Remediation
SIMOTICS CONNECT 400:
All versions < V0.5.0.0
Update to V0.5.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109778383/
SIMOTICS CONNECT 400:
All versions < V1.0.0.0
only affected by CVE-2021-31344, CVE-2021-31346, CVE-2021-31890
Update to V1.0.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109778383/

CVSS v3.1 Base Score 5.3
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C
CWE: CWE-843: Access of Resource Using Incompatible Type (‘Type Confusion’)

CVSS v3.1 Base Score 8.2
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C
CWE: CWE-1284: Improper Validation of Specified Quantity in Input

CVSS v3.1 Base Score 7.5
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
CWE: CWE-191: Integer Underflow (Wrap or Wraparound)

CVSS v3.1 Base Score 7.5
CVSS Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
CWE: CWE-240: Improper Handling of Inconsistent Structural Elements

https://www.siemens.com/cert/advisories