Publication Date: | 2017-05-08 |
Last Update: | 2022-02-08 |
Current Version: | V3.4 |
CVSS v3.1 Base Score: | 6.5 |
Affected Product and Versions | Remediation |
---|---|
Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller: All versions < V4.1.1 Patch04 | Update to V4.1.1 Patch04 or newer https://support.industry.siemens.com/cs/ww/en/view/109755160/ See further recommendations from section Workarounds and Mitigations |
Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200: All versions < V4.2.1 Patch03 | Update to V4.2.1 Patch03 or newer https://support.industry.siemens.com/cs/ww/en/view/109755151/ See further recommendations from section Workarounds and Mitigations |
Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P: All versions < V4.4.0 Patch01 | Update to V4.4.0 Patch01 or newer https://support.industry.siemens.com/cs/ww/en/view/109750012/ See further recommendations from section Workarounds and Mitigations |
IE/AS-i Link PN IO: All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
IE/PB-Link (incl. SIPLUS NET variants): All versions < V3.0 | Upgrade to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109744504/ See further recommendations from section Workarounds and Mitigations |
SCALANCE M-800 / S615: All versions < V4.03 | Update to V5.00 https://support.industry.siemens.com/cs/ww/en/view/109757544/ See further recommendations from section Workarounds and Mitigations |
SCALANCE W700: All versions < V6.1 | Update to V6.3.1 https://support.industry.siemens.com/cs/ww/en/view/109760470/ See further recommendations from section Workarounds and Mitigations |
SCALANCE X408: All versions < V4.1.0 | Update to V4.1.2 https://support.industry.siemens.com/cs/ww/en/view/109753720/ See further recommendations from section Workarounds and Mitigations |
SCALANCE X414: All versions < V3.10.2 | Update to V3.10.2 https://support.industry.siemens.com/cs/ww/en/view/109747276/ See further recommendations from section Workarounds and Mitigations |
SCALANCE X-200 switch family (incl. SIPLUS NET variants): All versions < V5.2.2 | Update to V5.2.2 https://support.industry.siemens.com/cs/ww/en/view/109752018/ See further recommendations from section Workarounds and Mitigations |
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants): All versions < V5.4.0 | Update to V5.4.0 https://support.industry.siemens.com/cs/ww/en/view/109755950/ See further recommendations from section Workarounds and Mitigations |
SCALANCE X-300 switch family (incl. SIPLUS NET variants): All versions < V4.1.0 | Update to V4.1.2 https://support.industry.siemens.com/cs/ww/en/view/109753720/ See further recommendations from section Workarounds and Mitigations |
SCALANCE XM-400 Family: All versions < V6.1 | Update to V6.2 or later version https://support.industry.siemens.com/cs/ww/en/view/109761424/ See further recommendations from section Workarounds and Mitigations |
SCALANCE XR-500 Family: All versions < V6.1 | Update to V6.2 or later version https://support.industry.siemens.com/cs/ww/en/view/109761425/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CM 1542-1: All versions < V2.0 | Update to V2.0 https://support.industry.siemens.com/cs/ww/en/view/109744924/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CM 1542SP-1: All versions < V1.0.15 | Update to V1.0.15 https://support.industry.siemens.com/cs/ww/en/view/109749255/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 343-1 (incl. SIPLUS variants): All versions < V3.1.3 | Update to V3.1.3 https://support.industry.siemens.com/cs/ww/en/view/109756088/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 343-1 Advanced (incl. SIPLUS variants): All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
SIMATIC CP 343-1 Lean (incl. SIPLUS variants): All versions < V3.1.3 | Update to V3.1.3 https://support.industry.siemens.com/cs/ww/en/view/109756088/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 443-1 (incl. SIPLUS variants): All versions < V3.2.17 | Update to V3.2.17 https://support.industry.siemens.com/cs/ww/en/view/109745387/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 443-1 Advanced (incl. SIPLUS variants): All versions < V3.2.17 | Update to V3.2.17 https://support.industry.siemens.com/cs/ww/en/view/109745388/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 443-1 OPC UA: All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC CP 1243-1 (incl. SIPLUS variants): All versions < V2.1.82 | Update to V3.1 https://support.industry.siemens.com/cs/ww/en/view/109757489/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants): All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
SIMATIC CP 1243-1 IEC (incl. SIPLUS variants): All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
SIMATIC CP 1243-1 IRC (incl. SIPLUS variants): All versions < V2.1.82 | Update to V3.1 https://support.industry.siemens.com/cs/ww/en/view/109757489/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants): All versions < V1.0.15 | Update to V1.0.15 https://support.industry.siemens.com/cs/ww/en/view/109749255/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1543-1 (incl. SIPLUS variants): All versions < V2.1 | Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109747253/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1543SP-1 (incl. SIPLUS variants): All versions < V1.0.15 | Update to V1.0.15 https://support.industry.siemens.com/cs/ww/en/view/109749255/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1604: All versions < V2.7 | Update to V2.8.0 https://support.industry.siemens.com/cs/ww/en/view/109762689/ See further recommendations from section Workarounds and Mitigations |
SIMATIC CP 1616: All versions < V2.7 | Update to V2.8.0 https://support.industry.siemens.com/cs/ww/en/view/109762689/ See further recommendations from section Workarounds and Mitigations |
SIMATIC DK-16xx PN IO: All versions < V2.7 | Update to V2.8.0 https://support.industry.siemens.com/cs/ww/en/view/109762689/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200AL: All versions < V1.0.2 | Update to V1.0.2 https://support.industry.siemens.com/cs/ww/en/view/109479281/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200M (incl. SIPLUS variants): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200MP IM155-5 PN BA (incl. SIPLUS variants): All versions < V4.0.1 | Update to V4.0.1 or newer https://support.industry.siemens.com/cs/ww/en/view/109754281/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants): All versions < V4.2 | Update to V4.2 https://support.industry.siemens.com/cs/ww/en/view/93012181/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants): All versions < V4.1 | Update to V4.1 https://support.industry.siemens.com/cs/ww/en/view/78647504/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200pro: All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200S (incl. SIPLUS variants): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200SP (incl. SIPLUS variants, except IM155-6 PN ST and IM155-6 PN HF): All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants): All versions < 4.2.0 | Update to V4.2.0 https://support.industry.siemens.com/cs/ww/en/view/85624387/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200SP IM155-6 PN HS (incl. SIPLUS variants): All versions < V4.0.1 | Update to V4.0.1 https://support.industry.siemens.com/cs/ww/en/view/109795369/ See further recommendations from section Workarounds and Mitigations |
SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants): All versions < V4.1.0 | Update to V4.1.0 https://support.industry.siemens.com/cs/de/de/view/78648144/ See further recommendations from section Workarounds and Mitigations |
SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants): All versions < V15.1 | Update to V15.1 https://support.industry.siemens.com/cs/ww/en/view/109761576/ See further recommendations from section Workarounds and Mitigations |
SIMATIC MV400 family: All Versions < V7.0.6 | Update to V7.0.6 https://support.industry.siemens.com/cs/ww/en/view/109793481/ See further recommendations from section Workarounds and Mitigations |
SIMATIC PN/PN Coupler (incl. SIPLUS NET variants): All versions < V4.0 | Upgrade to V4.0 https://support.industry.siemens.com/cs/ww/en/view/109749637/ See further recommendations from section Workarounds and Mitigations |
SIMATIC RF650R: All versions < V3.0 | Update to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109743740/ See further recommendations from section Workarounds and Mitigations |
SIMATIC RF680R: All versions < V3.0 | Update to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109743740/ See further recommendations from section Workarounds and Mitigations |
SIMATIC RF685R: All versions < V3.0 | Update to V3.0 https://support.industry.siemens.com/cs/ww/en/view/109743740/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-200 SMART: All versions < V2.3 | Contact your local Siemens representative or the Siemens customer support at https://w3.siemens.com/aspa_app/ to receive firmware version 2.3. Update to V2.3 See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions < V3.X.14 | Update to V3.X.14 https://support.industry.siemens.com/cs/ww/en/ps/13752/dl See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants): All versions < V6.0.7 | Update to V6.0.7 https://support.industry.siemens.com/cs/ww/en/view/109474550/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants): All versions < V6.0.6 | Update to V6.0.6 https://support.industry.siemens.com/cs/ww/en/view/109474874/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants): All versions < V7.0.2 | Update to V7.0.2 https://support.industry.siemens.com/cs/ww/en/view/109752685/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-410 CPU family (incl. SIPLUS variants): All versions < V8.2 | Update to V8.2 https://support.industry.siemens.com/cs/ww/en/view/109476571/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions < V4.2.1 | Update to V4.2.1 https://support.industry.siemens.com/cs/ww/en/view/109741461/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions < V2.1 | Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109478459/ See further recommendations from section Workarounds and Mitigations |
SIMATIC S7-1500 Software Controller (incl. F): All versions < V2.1 | Update to V2.1 https://support.industry.siemens.com/cs/ww/en/view/109478528/ See further recommendations from section Workarounds and Mitigations |
SIMATIC TDC CP51M1: All versions < V1.1.8 | Update to V1.1.8 https://support.industry.siemens.com/cs/ww/en/view/27049282/ See further recommendations from section Workarounds and Mitigations |
SIMATIC TDC CPU555: All versions < V1.1.1 | Update to V1.1.1 https://support.industry.siemens.com/cs/ww/en/view/109740119/ See further recommendations from section Workarounds and Mitigations |
SIMATIC Teleservice Adapter IE Advanced: All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC Teleservice Adapter IE Basic: All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC Teleservice Adapter IE Standard: All versions |
Currently no remediation is planned See recommendations from section Workarounds and Mitigations |
SIMATIC WinAC RTX (F) 2010: All versions < SIMATIC WinAC RTX 2010 SP3 | Update to SIMATIC WinAC RTX 2010 SP3 and apply BIOS and Microsoft Windows updates https://support.industry.siemens.com/cs/ww/en/view/109765109/ See further recommendations from section Workarounds and Mitigations |
SIMOCODE pro V PN (incl. SIPLUS variants): All versions < V2.0.0 | Update to V2.0.0 https://support.industry.siemens.com/cs/ww/en/view/109749989/ See further recommendations from section Workarounds and Mitigations |
SIMOTION (incl. SIPLUS variants): All versions < V4.5 HF1 | Update to V4.5 HF1 https://support.industry.siemens.com/cs/ww/en/view/109742328/ See further recommendations from section Workarounds and Mitigations |
SINAMICS DCM w. PN: All versions < V1.4 SP1 HF5 | Update to V1.4 SP1 HF5 https://support.industry.siemens.com/cs/ww/en/view/44029688/ See further recommendations from section Workarounds and Mitigations |
SINAMICS DCP w. PN: All versions < V1.2 HF1 | Update to V1.2 HF1 https://support.industry.siemens.com/cs/ww/en/view/109474935/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G110M w. PN: All versions < V4.7 SP6 HF3 | Update to V4.7 SP6 HF3 https://support.industry.siemens.com/cs/ww/en/view/109482659/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants): All versions < V4.7 SP6 HF3 | Update to V4.7 SP6 HF3 https://support.industry.siemens.com/cs/ww/en/view/109482659/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G130 V4.7 w. PN: All versions < V4.7 HF27 | Update to V4.7 HF27 https://support.industry.siemens.com/cs/ww/en/view/103433117/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G130 V4.8 w. PN: All versions < V4.8 HF4 | Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109742040/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G150 V4.7 w. PN: V4.7: All versions < V4.7 HF27 | Update to V4.7 HF27 https://support.industry.siemens.com/cs/ww/en/view/103433117/ See further recommendations from section Workarounds and Mitigations |
SINAMICS G150 V4.8 w. PN: All versions < V4.8 HF4 | Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109742040/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S110 w. PN: All versions < V4.4 SP3 HF5 | Update V4.4 SP3 HF5 https://support.industry.siemens.com/cs/ww/en/view/109474320/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants): All versions < V4.7 | Update to latest version of V5.1 SP1 https://support.industry.siemens.com/cs/ww/en/view/109758423/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants): All versions | Update to latest version of V5.1 SP1 https://support.industry.siemens.com/cs/ww/en/view/109758423/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants): All versions < V4.7 HF27 | Update to V4.7 HF27 https://support.industry.siemens.com/cs/ww/en/view/92522512/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants): All versions < V4.8 HF4 | Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109740193/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S150 V4.7 w. PN: All versions < V4.7 HF27 | Update to V4.7 HF27 https://support.industry.siemens.com/cs/ww/en/view/103433117/ See further recommendations from section Workarounds and Mitigations |
SINAMICS S150 V4.8 w. PN: All versions < V4.8 HF4 | Update to V4.8 HF4 https://support.industry.siemens.com/cs/ww/en/view/109742040/ See further recommendations from section Workarounds and Mitigations |
SINAMICS V90 w. PN: All versions < V1.01 | Update to V1.01 https://support.industry.siemens.com/cs/ww/en/view/109746210/ See further recommendations from section Workarounds and Mitigations |
SINUMERIK 828D V4.5 and prior: All versions < V4.5 SP6 HF2 | Update to V4.5 SP6 HF2 SINUMERIK software can be obtained from your local Siemens account manager See further recommendations from section Workarounds and Mitigations |
SINUMERIK 828D V4.7: All versions < V4.7 SP4 HF1 | Update to V4.7 SP4 HF1. SINUMERIK software can be obtained from your local Siemens account manager See further recommendations from section Workarounds and Mitigations |
SINUMERIK 840D sl V4.5 and prior: All versions < V4.5 SP6 HF2 | Update to V4.5 SP6 HF2 SINUMERIK software can be obtained from your local Siemens account manager See further recommendations from section Workarounds and Mitigations |
SINUMERIK 840D sl V4.7: All versions < V4.7 SP4 HF1 | Update to V4.7 SP4 HF1 SINUMERIK software can be obtained from your local Siemens account manager See further recommendations from section Workarounds and Mitigations |
SIRIUS ACT 3SU1 interface module PROFINET: All versions < V1.1.0 | Update to V1.1.0 https://support.industry.siemens.com/cs/ww/en/view/109753683/ See further recommendations from section Workarounds and Mitigations |
SIRIUS Motor Starter M200D PROFINET: All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
SIRIUS Soft Starter 3RW44 PN: All versions |
Currently no remediation is available See recommendations from section Workarounds and Mitigations |
SITOP PSU8600 PROFINET: All versions < V1.2.0 | Update to V1.2.0 https://support.industry.siemens.com/cs/ww/en/view/102295547/ See further recommendations from section Workarounds and Mitigations |
SITOP UPS1600 PROFINET (incl. SIPLUS variants): All versions < V2.2.0 | Update to V2.2.0 https://support.industry.siemens.com/cs/ww/en/view/79207181/ See further recommendations from section Workarounds and Mitigations |
Softnet PROFINET IO for PC-based Windows systems: All versions < V14 SP1 | Upgrade to V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109747482/ See further recommendations from section Workarounds and Mitigations |
CVSS v3.1 Base Score | 6.5 |
CVSS Vector | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C |
CWE: | CWE-400: Uncontrolled Resource Consumption |
CVSS v3.1 Base Score | 6.5 |
CVSS Vector | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C |
CWE: | CWE-400: Uncontrolled Resource Consumption |