Publication Date: |
|
Last Update: |
|
Current Version: | V1.0 |
CVSS v3.1 Base Score: | 8.8 |
CVSS v4.0 Base Score: | 9.3 |
Affected Product and Versions | Remediation |
---|---|
All versions only if WibuKey Dongles are used affected by all CVEs |
Update WibuKey Runtime for Windows to V6.70 or later version (https://www.wibu.com/us/support/user/downloads-user-software.html).
|
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
CVSS v3.1 Base Score | 8.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H |
CVSS v4.0 Base Score | 9.3 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H |
CWE | CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer |
CVSS v3.1 Base Score | 6.5 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H |
CVSS v4.0 Base Score | 8.2 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H |
CWE | CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer |
Beyond the affected Siemens client applications listed above, there is a range of Siemens EDA/DISW client applications, that also support the use of WibuKey Dongles as part of the Siemens Advanced Licensing Technology (SALT).
Siemens recommends to update the driver "WibuKey Runtime for Windows" to V6.70 or later version on all Windows clients, where WibuKey Dongles are used. The latest version of the driver can be downloaded from the WIBU Systems website [3].
[3] https://www.wibu.com/us/support/user/downloads-user-software.html
V1.0 (2024-10-08): | Publication Date |