As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
PRODUCT DESCRIPTION
RUGGEDCOM CROSSBOW is a secure access management solution designed to provide NERC CIP compliant access to Intelligent Electronic Devices.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory.
Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Vulnerability CVE-2026-89196
Affected devices do not properly validate or sanitize input in facility names processed during the Bulk Import/Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Vulnerability CVE-2026-89197
Affected devices do not properly validate or sanitize input in the Value field of notification conditions processed during the Notification Profile configuration. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Vulnerability CVE-2026-89198
Affected devices do not properly validate or sanitize the filename of firmware files uploaded to the system. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Vulnerability CVE-2026-89199
Affected devices do not properly restrict access to sensitive configuration items via specific database queries. This could allow an authenticated attacker to retrieve administrative credentials for various internal systems, leading to unauthorized information disclosure and privilege escalation.
CWE-639: Authorization Bypass Through User-Controlled Key
Vulnerability CVE-2026-89200
Affected devices do not properly validate or sanitize input in the Name and Value fields for custom file labels. This could allow an authenticated attacker with administrative privileges to execute arbitrary SQL commands on the underlying database.
CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Vulnerability CVE-2026-89201
Affected devices do not properly validate or sanitize input in device group or facility names processed during the Bulk Export workflow. This could allow an authenticated attacker with specific privileges to execute arbitrary SQL commands on the underlying database.
CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Vulnerability CVE-2026-89202
Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.
CWE-639: Authorization Bypass Through User-Controlled Key
Vulnerability CVE-2026-89203
Affected devices do not properly restrict access to various database queries, allowing users to retrieve system-wide information that is not intended for their privilege level. This could allow an authenticated attacker to gather sensitive information about the system's infrastructure, including details on all devices, substations, users, and scheduled activities.
CWE-201: Insertion of Sensitive Information Into Sent Data
Vulnerability CVE-2026-89204
Affected devices do not properly restrict access to database queries used for subnet management. This could allow an authenticated attacker to read, modify, or delete subnet configurations, leading to unauthorized information disclosure and data manipulation.
CWE-639: Authorization Bypass Through User-Controlled Key
Vulnerability CVE-2026-89205
Affected devices do not properly perform server-side authorization checks for requests to schedule special operations. This could allow an authenticated attacker with minimal privileges to schedule unauthorized operations on devices.
CWE-602: Client-Side Enforcement of Server-Side Security
Vulnerability CVE-2026-89206
Affected devices do not properly perform server-side authorization checks for requests to modify the state of scheduled actions. This could allow an authenticated attacker with minimal privileges to retry, stop, or delete scheduled tasks without proper authorization.
CWE-602: Client-Side Enforcement of Server-Side Security
ADDITIONAL INFORMATION
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:
https://www.siemens.com/cert/advisories