Publication Date: |
|
Last Update: |
|
Current Version: | V1.0 |
CVSS v3.1 Base Score: | 6.7 |
CVSS v4.0 Base Score: | 5.4 |
Affected Product and Versions | Remediation |
---|---|
All versions < V4.3 affected by all CVEs |
Update to V4.3 or later version
|
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
CVSS v3.1 Base Score | 6.7 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H |
CVSS v4.0 Base Score | 5.4 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CWE | CWE-269: Improper Privilege Management |
CVSS v3.1 Base Score | 6.7 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H |
CVSS v4.0 Base Score | 5.4 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CWE | CWE-295: Improper Certificate Validation |
V1.0 (2025-04-08): | Publication Date |