Publication Date:
Last Update:
Current Version: V1.0
CVSS v3.1 Base Score: 8.7
CVSS v4.0 Base Score: 9.4
Un-/Collapse All
Affected Product and Versions Remediation

All versions < V4.3.0
affected by CVE-2026-124981
Update to V4.3.0 or later version



All versions < V6.0.0
affected by CVE-2026-124981
Update to V6.0.0 or later version



All versions < V6.0.0
affected by CVE-2026-124981
Update to V6.0.0 or later version


  • Ensure that Resource Servers independently validate the cryptographic signature of incoming JWTs before accepting them, rather than relying solely on the OIDC Provider's Token Introspection endpoint to verify token validity.

Product-specific remediations or mitigations can be found in the section Known Affected Products.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 8.7
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N
CVSS v4.0 Base Score 9.4
CVSS v4.0 Vector CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N
CWE CWE-347: Improper Verification of Cryptographic Signature

https://www.siemens.com/cert/advisories
V1.0 (2026-11-27): Publication Date