Publication Date: |
|
Last Update: |
|
Current Version: | V1.0 |
CVSS v3.1 Base Score: | 7.8 |
CVSS v4.0 Base Score: | 8.5 |
Affected Product and Versions | Remediation |
---|---|
All versions < V3.0.6 affected by all CVEs |
Update to V3.0.6 or later version
|
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
The affected application improperly validates code signing certificates. This could allow an attacker to bypass the check and exceute arbitrary code during installations.
CVSS v3.1 Base Score | 6.2 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C |
CVSS v4.0 Base Score | 6.9 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N |
CWE | CWE-347: Improper Verification of Cryptographic Signature |
CVSS v3.1 Base Score | 7.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CVSS v4.0 Base Score | 8.5 |
CVSS v4.0 Vector | CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
CWE | CWE-284: Improper Access Control |
V1.0 (2025-07-08): | Publication Date |