Publication Date:
Last Update:
Current Version: V1.2
CVSS v3.1 Base Score: 8.2
CVSS v4.0 Base Score: 6.9
Un-/Collapse All
Affected Product and Versions Remediation

All versions
affected by all CVEs
Currently no fix is available

All versions < V2303
affected by all CVEs
Update to V2303 or later version
  • CVE-2021-31344, CVE-2021-31345, CVE-2021-31346, CVE-2021-31889, CVE-2021-31890: Apply network segmentation and put the ECUs behind properly configured gateways/firewalls
  • CVE-2021-31881, CVE-2021-31882, CVE-2021-31883: Disable DHCP client functionality, if feature not used, by deselecting the TcpIpIpV4General/TcpIpDhcpClientEnabled Pre-Compile configuration option

Product-specific remediations or mitigations can be found in the section Affected Products and Solution.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 5.3
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
CVSS v4.0 Base Score 6.9
CVSS v4.0 Vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
CWE CWE-843: Access of Resource Using Incompatible Type ('Type Confusion')
CVSS v3.1 Base Score 7.5
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE CWE-1284: Improper Validation of Specified Quantity in Input
CVSS v3.1 Base Score 8.2
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
CWE CWE-1284: Improper Validation of Specified Quantity in Input
CVSS v3.1 Base Score 7.1
CVSS v3.1 Vector CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
CWE CWE-125: Out-of-bounds Read
CVSS v3.1 Base Score 6.5
CVSS v3.1 Vector CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CVSS v3.1 Base Score 7.1
CVSS v3.1 Vector CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
CWE CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
CVSS v3.1 Base Score 7.5
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE CWE-191: Integer Underflow (Wrap or Wraparound)
CVSS v3.1 Base Score 7.5
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CWE CWE-240: Improper Handling of Inconsistent Structural Elements

Products listed in this advisory use Nucleus NET, the networking stack of Nucleus RTOS (Real-time operating system).

For more details regarding the vulnerabilities reported for Nucleus RTOS refer to Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/html/ssa-044112.html

https://www.siemens.com/cert/advisories
V1.0 (2021-12-14): Publication Date
V1.1 (2022-11-08): Removed CVE-2021-31884 as Capital VSTAR is not affected
V1.2 (2024-10-08): Renamed Capital VSTAR to Capital Embedded AR Classic; added fix for version line R20-11