Publication Date: |
|
Last Update: |
|
Current Version: | V1.1 |
CVSS v3.1 Base Score: | 9.1 |
Affected Product and Versions | Remediation |
---|---|
All versions affected by all CVEs |
Install the patch (available at https://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions
|
All versions affected by all CVEs |
Install the patch (available at https://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions
|
All versions affected by all CVEs |
Install the patch (available at https://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions
|
All versions affected by CVE-2023-3935 |
Install the patch (available at https://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions
|
All versions >= V4.0 affected by all CVEs |
Install the patch (available at https://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions
|
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.
An unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).
CVSS v3.1 Base Score | 9.1 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C |
CWE | CWE-126: Buffer Over-read |
A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.
An unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).
CVSS v3.1 Base Score | 7.5 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C |
CWE | CWE-126: Buffer Over-read |
In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To exploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)
CVSS v3.1 Base Score | 9.0 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-122: Heap-based Buffer Overflow |
For more details regarding the vulnerabilities in CodeMeter Runtime refer to:
V1.0 (2023-11-14): | Publication Date |
V1.1 (2024-08-13): | Added SENTRON powermanager |