Publication Date:
Last Update:
Current Version: V1.2
CVSS v3.1 Base Score: 6.7
Un-/Collapse All
Affected Product and Versions Remediation

All versions
affected by CVE-2022-35868
Currently no fix is planned
Migrate to TIA Project-Server V1.1 or later version

All versions < V15.1 Update 8
affected by CVE-2022-35868
Update to V15.1 Update 8 or later version
Migrate to TIA Project-Server V1.1 or later version

All versions < V1.1
affected by CVE-2022-35868

All versions
affected by CVE-2022-35868
Currently no fix is planned
Migrate to TIA Project-Server V1.1 or later version

All versions < V17 Update 6
affected by CVE-2022-35868
Update to V17 Update 6 or later version
Migrate to TIA Project-Server V1.1 or later version
  • Make sure that the directory that is set as working directory when starting the TIA Project-Server or TIA Multiuser Server does not contain untrusted files.

Product-specific remediations or mitigations can be found in the section Affected Products and Solution.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 6.7
CVSS v3.1 Vector CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
CWE CWE-426: Untrusted Search Path

Previous versions of the TIA Project-Server or Multiuser Server were delivered together with the TIA Portal from V14. These are the following server versions: Multiuser-Server V14,V14 SP1, V15 and V15.1 as well as TIA Project-Server V16 and V17.

The TIA Project-Server version does not follow the TIA Portal version anymore and the version numbering started with version V1.0 again.

https://www.siemens.com/cert/advisories
V1.0 (2023-02-14): Publication Date
V1.1 (2023-05-09): Added fix for TIA Project-Server V17
V1.2 (2024-08-13): Clarify no fix planned for TIA Project-Server V16