Publication Date:
Last Update:
Current Version: V1.3
CVSS v3.1 Base Score: 8.6
Un-/Collapse All
Affected Product and Versions Remediation
Expand children
Expand children
  • Deactivate the TCP Event feature (not active by default)
  • Restrict access to the TCP Event Service port (default 26864/tcp) to trusted networks and client IP addresses

Product-specific remediations or mitigations can be found in the section Affected Products and Solution.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 8.6
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C
CWE CWE-20: Improper Input Validation

  • Martin Grubhofer and Michael Messner from Siemens Energy for reporting the vulnerability

https://www.siemens.com/cert/advisories
V1.0 (2022-10-11): Publication Date
V1.1 (2023-01-10): Added fix for SCALANCE W-700 IEEE 802.11ax product family
V1.2 (2023-03-14): Added missing affected products SCALANCE S615 EEC (6GK5615-0AA01-2AA2) and SCALANCE M876-4 (6GK5876-4AA10-2BA2)
V1.3 (2025-02-11): Corrected fix for CVE-2022-31766 for SCALANCE W-700 IEEE 802.11ax family devices