Publication Date: |
|
Last Update: |
|
Current Version: | V1.3 |
CVSS v3.1 Base Score: | 7.5 |
Affected Product and Versions | Remediation |
---|---|
All versions with Fortinet NGFW < V7.4.4 |
Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.
|
Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk:
Product-specific remediations or mitigations can be found in the section
Affected Products and Solution.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
CVSS v3.1 Base Score | 6.7 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-121: Stack-based Buffer Overflow |
CVSS v3.1 Base Score | 1.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C |
CWE | CWE-916: Use of Password Hash With Insufficient Computational Effort |
CVSS v3.1 Base Score | 6.8 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') |
CVSS v3.1 Base Score | 7.5 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') |
CVSS v3.1 Base Score | 7.5 |
CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
CWE | CWE-121: Stack-based Buffer Overflow |
CVSS v3.1 Base Score | 3.4 |
CVSS v3.1 Vector | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:N/E:F/RL:W/RC:R |
CWE | CWE-1389: Incorrect Parsing of Numbers with Different Radices |
CVSS v3.1 Base Score | 5.1 |
CVSS v3.1 Vector | CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RC:R |
CWE | CWE-284: Improper Access Control |
Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications. Fortinet provides a public RSS feed for their security alerts to which customers can also subscribe [1].
[1] https://filestore.fortinet.com/fortiguard/rss/ir.xml
V1.0 (2024-07-09): | Publication Date |
V1.1 (2024-08-13): | Updated CVE-2024-23111 description and added newly published CVE-2024-26006 and CVE-2024-26015 |
V1.2 (2024-09-10): | Added newly published upstream vulnerability CVE-2024-36505 |
V1.3 (2024-10-08): | Added fix for Fortinet NGFW as released from Siemens for RUGGEDCOM APE1808; added mitigations for CVE-2024-26006 and CVE-2024-26010 |