As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
PRODUCT DESCRIPTION
SINEC Traffic Analyzer is an on-premise application that monitors PNIO (PROFINET IO) communication between Controller and IO devices. This software detects the PROFINET communication issues and reports to user via Web-UI.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory.
Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Vulnerability CVE-2024-41903
The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption.
The affected application do not properly enforce restriction of excessive authentication attempts. This could allow an unauthenticated attacker to conduct brute force attacks against legitimate user credentials or keys.
CWE-307: Improper Restriction of Excessive Authentication Attempts
Vulnerability CVE-2024-41905
The affected application do not have access control for accessing the files. This could allow an authenticated attacker with low privilege's to get access to sensitive information.
The affected application does not properly handle cacheable HTTP responses in the web service. This could allow an attacker to read and modify data stored in the local cache.
CWE-524: Use of Cache Containing Sensitive Information
Vulnerability CVE-2024-41907
The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack.
CWE-358: Improperly Implemented Security Check for Standard
ADDITIONAL INFORMATION
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:
https://www.siemens.com/cert/advisories
HISTORY DATA
V1.0 (2024-08-13):
Publication Date
TERMS OF USE
Siemens Security Advisories are subject to the terms and conditions contained in Siemens’ underlying
license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License
Terms"). To the extent applicable to information, software or documentation made available in or through
a Siemens Security Advisory, the Terms of Use of Siemens’ Global Website (https://www.siemens.com/
terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply