As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
PRODUCT DESCRIPTION
RUGGEDCOM CROSSBOW is a secure access management solution designed to provide NERC CIP compliant access to Intelligent Electronic Devices.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory.
Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Vulnerability CVE-2025-6965
There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above.
An information disclosure issue in the zipfileInflate function in the zipfile extension in SQLite v3.51.1 and earlier allows attackers to obtain heap memory via supplying a crafted ZIP file.
CVSS v3.1 Base Score
7.5
CVSS v3.1 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE
CWE-244: Improper Clearing of Heap Memory Before Release ('Heap Inspection')
Vulnerability CVE-2025-71316
SQLite 'sqldiff.exe' does not securely handle the way the Microsoft Windows C runtime converts Unicode characters to ANSI codepages. An attacker could use the '-L' option to load an arbitrary DLL with a crafted command line argument string that results in command line file arguments being misinterpreted as command line options. Fixed on or around 2025-12-26.
SQLite before 3.53.2 contains memory corruption vulnerabilities in the FTS5 full-text search extension that allow attackers to cause process crashes, memory exhaustion, or arbitrary code execution by supplying a crafted database with malformed FTS5 page data. Attackers can trigger an out-of-bounds read in fts5LeafSeek() via an attacker-controlled loop bound and a heap buffer overflow write in fts5ChunkIterate() through a crafted continuation page causing an integer underflow, exploitable when an FTS5 MATCH query is executed against the malicious database.
SQLite before 3.53.2 contains a heap-based buffer overflow vulnerability in the FTS5 full-text search extension that allows attackers to cause a crash or execute arbitrary code by supplying a crafted database with malicious continuation page metadata specifying a szLeaf value smaller than 4. Attackers can trigger an integer underflow in fts5ChunkIterate() causing an inflated remaining byte count during FTS5 MATCH query processing, leading to a heap buffer overflow of attacker-controlled data in applications compiled with SQLITE_ENABLE_FTS5.
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:
https://www.siemens.com/cert/advisories