| Publication Date: |
|
| Last Update: |
|
| Current Version: | V1.0 |
| CVSS v3.1 Base Score: | 5.4 |
| CVSS v4.0 Base Score: | 6.8 |
Product-specific remediations or mitigations can be found in the section
Known Affected Products.
Please follow the General Security Recommendations.
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline. This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user.
| CVSS v3.1 Base Score | 5.4 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N |
| CVSS v4.0 Base Score | 6.8 |
| CVSS v4.0 Vector | CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:A/VC:N/VI:H/VA:N/SC:N/SI:H/SA:N |
| CWE | CWE-94: Improper Control of Generation of Code ('Code Injection') |
| V1.0 (2026-06-30): | Publication Date |