Publication Date:
Last Update:
Current Version: V1.0
CVSS v3.1 Base Score: 9.1
CVSS v4.0 Base Score: 9.1
Un-/Collapse All
Affected Product and Versions Remediation

All versions
affected by CVE-2026-7891
Review mendix access rules knowing that System.User has built-in platform-enforced access rules that cannot be overridden or restricted by access rules defined on a specialization. Check updated documentation for further details

  • Any security model relying solely on XPath constraints on a System.User specialization to restrict access should be revised to enforce restrictions at the App Security role-management configuration level instead.

Product-specific remediations or mitigations can be found in the section Known Affected Products.
Please follow the General Security Recommendations.

As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

Un-/Collapse All

This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.

CVSS v3.1 Base Score 9.1
CVSS v3.1 Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
CVSS v4.0 Base Score 9.1
CVSS v4.0 Vector CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
CWE CWE-277: Insecure Inherited Permissions

https://www.siemens.com/cert/advisories
V1.0 (2026-07-14): Publication Date