As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
PRODUCT DESCRIPTION
The RUGGEDCOM APE1808 is a powerful utility-grade application hosting platform that lets you deploy a range of commercially available applications for edge computing and cybersecurity in harsh, industrial environments.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory.
Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Vulnerability CVE-2022-0028
A PAN-OS URL filtering policy misconfiguration could allow a network-based attacker to conduct reflected and amplified TCP denial-of-service (RDoS) attacks. The DoS attack would appear to originate from a Palo Alto Networks PA-Series (hardware), VM-Series (virtual) and CN-Series (container) firewall against an attacker-specified target. To be misused by an external attacker, the firewall configuration must have a URL filtering profile with one or more blocked categories assigned to a source zone that has an external facing interface. This configuration is not typical for URL filtering and, if set, is likely unintended by the administrator. If exploited, this issue would not impact the confidentiality, integrity, or availability of our products. However, the resulting denial-of-service (DoS) attack may help obfuscate the identity of the attacker and implicate the firewall as the source of the attack. We have taken prompt action to address this issue in our PAN-OS software. All software updates for this issue are expected to be released no later than the week of August 15, 2022. This issue does not impact Panorama M-Series or Panorama virtual appliances. This issue has been resolved for all Cloud NGFW and Prisma Access customers and no additional action is required from them.
CWE-406: Insufficient Control of Network Message Volume (Network Amplification)
Vulnerability CVE-2023-0005
A vulnerability in Palo Alto Networks PAN-OS software enables an authenticated administrator to expose the plaintext values of secrets stored in the device configuration and encrypted API keys.
CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere
Vulnerability CVE-2023-0008
A file disclosure vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-write administrator with access to the web interface to export local files from the firewall through a race condition.
A DOM-Based cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS software enables a remote attacker to execute a JavaScript payload in the context of an administrator’s browser when they view a specifically crafted link to the PAN-OS web interface.
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Vulnerability CVE-2023-6791
A credential disclosure vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-only administrator to obtain the plaintext credentials of stored external system integrations such as LDAP, SCP, RADIUS, TACACS+, and SNMP from the web interface.
A vulnerability exists in Palo Alto Networks PAN-OS software that enables an authenticated administrator with the privilege to commit a specifically created configuration to read local files and resources from the system.
CWE-610: Externally Controlled Reference to a Resource in Another Sphere
Vulnerability CVE-2024-5911
An arbitrary file upload vulnerability in Palo Alto Networks Panorama software enables an authenticated read-write administrator with access to the web interface to disrupt system processes and crash the Panorama. Repeated attacks eventually cause the Panorama to enter maintenance mode, which requires manual intervention to bring the Panorama back online.
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT:
https://www.siemens.com/cert/advisories
HISTORY DATA
V1.0 (2024-04-09):
Publication Date
V1.1 (2024-08-13):
Added newly published CVE-2024-5911
TERMS OF USE
Siemens Security Advisories are subject to the terms and conditions contained in Siemens’ underlying
license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License
Terms"). To the extent applicable to information, software or documentation made available in or through
a Siemens Security Advisory, the Terms of Use of Siemens’ Global Website (https://www.siemens.com/
terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply
additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.