| Publication Date: |
|
| Last Update: |
|
| Current Version: | V1.0 |
| CVSS v3.1 Base Score: | 9.1 |
| CVSS v4.0 Base Score: | 6.4 |
| Affected Product and Versions | Remediation |
|---|---|
|
All versions < V23.3 HotfixRev27 affected by CVE-2026-3014 |
Update to V23.3 HotfixRev27 or later version
|
|
All versions < V24.1 HotfixRev16 affected by CVE-2026-3014 |
Update to V24.1 HotfixRev16 or later version
|
|
All versions < V25.1 HotfixRev15 affected by CVE-2026-3014 |
Update to V25.1 HotfixRev15 or later version
|
Product-specific remediations or mitigations can be found in the section
Known Affected Products.
Please follow the General Security Recommendations.
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
This chapter describes all vulnerabilities (CVE-IDs) addressed in this security advisory. Wherever applicable, it also documents the product-specific impact of the individual vulnerabilities.
Milestone has released a new version of XProtect® (and several cumulative patch updates) which fix security vulnerability in Management Server API.
The vulnerability causes users with edit permissions to the Management Server to be able to execute arbitrary code in context of the Management Server Service.
| CVSS v3.1 Base Score | 9.1 |
| CVSS v3.1 Vector | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| CVSS v4.0 Base Score | 6.4 |
| CVSS v4.0 Vector | CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H |
| CWE | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') |
For additional information regarding the vulnerability see the related Milestone Security Advisory:
| V1.0 (2026-08-11): | Publication Date |