-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-148641: XPath Constraint Vulnerability in Mendix Runtime Publication Date: 2022-03-08 Last Update: 2022-04-12 Current Version: 1.1 CVSS v3.1 Base Score: 6.8 SUMMARY ======= A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible attributes and modify sensitive data. Mendix has released updates for the affected product lines, recommends to update to the latest versions and to redeploy the applications. AFFECTED PRODUCTS AND SOLUTION ============================== * Mendix Applications using Mendix 7 - Affected versions: All versions < V7.23.29 - Remediation: Update to V7.23.29 or later version and redeploy your application - Download: https://docs.mendix.com/releasenotes/studio-pro/7.23/ * Mendix Applications using Mendix 8 - Affected versions: All versions < V8.18.16 - Remediation: Update to V8.18.16 or later version and redeploy your application - Download: https://docs.mendix.com/releasenotes/studio-pro/8.18/ * Mendix Applications using Mendix 9 - Affected versions: All deployments with Runtime Custom Setting _DataStorage.UseNewQueryHandler_ set to False - Remediation: Set Runtime Custom Setting _DataStorage.UseNewQueryHandler_ to True or remove the custom setting. The value is set to True by default - Download: https://docs.mendix.com/developerportal/deploy/environments-details#runtime-tab WORKAROUNDS AND MITIGATIONS =========================== Product specific remediations or mitigations can be found in the section "Affected Products and Solution". Please follow the "General Security Recommendations". GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== Mendix is a high productivity app platform that enables you to build and continuously improve mobile and web applications at scale. The Mendix Platform is designed to accelerate enterprise app delivery across your entire application development lifecycle, from ideation to deployment and operations. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2022-24309 If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data. CVSS v3.1 Base Score: 6.8 CVSS Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C CWE: CWE-284: Improper Access Control ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2022-03-08): Publication Date V1.1 (2022-04-12): Summary update; Default configuration for Mendix 9 is not affected; CVSS vector review TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. Copyright: Siemens 2022 -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmJUwQAACgkQlm7gTEmy ujSBdhAAijkO1ukKyLIUl6WoYLAVMCm6kXZloZ4SAVuF147aan5l8FZHaZ2p6gFx fg3dAc5fXQTck11wsjOlFP5TIW3cmLreIEG/PVxyMgdgzYJyu5sG3dGMhsRmzflG 9a7tvmWHRyiK66cwMvQQrHL3rFZU6d4o+zK6NxLF/HM2JEBE0Xqck++yjnVu/SQu ocR1Sche5Q1ZGuKq6lxKNzi/thIghxFVHbhzQjJaIrap0v+xqujnqTu4+/PFFw54 ckzgQot+DD3WBrq5vTJgfvYB4CkQqlUirY45mQXORTJXcRFN6kWyvqEMSLhm6S3J lf/NMDbg5q0xG2+Ev12SjYcLgBknXWDeP/iXQ4lwhAJ3dtR75W9FJjfnknlD/khv CM+BPxQDKdkrFM/bXBya9NFpPUtNanGj5Drp8WfuyemwJTE4pJq9eBuWfNy7z/L1 jgh9cR+bqjaPaD4fmkUcqikv0RemfaR3ehHrUZfjPJGinpHPlRVGIoBT9DVtgmZK qLyWH+jvE3ygWRp8TpzeN1uWDjne5Kv05YbeFPvgWFEe7WGgICX+qrptubc2jtKf LO7aUuaiCFNw4Nv0kK8QMgEDlgASgHuoz6mEsh5SpYANt1AEqhATSCGDSdD5hEvs pj8ZtoRZ68EJgAHl7E1i9QdUWGQqf1jKq52sAUFs5okpTKLVtWo= =myvO -----END PGP SIGNATURE-----