-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-166747: Scene File Parsing Vulnerability in Simcenter STAR-CCM+ Viewer before V2022.1 Publication Date: 2022-03-08 Last Update: 2022-03-08 Current Version: 1.0 CVSS v3.1 Base Score: 7.8 SUMMARY ======= Siemens Simcenter STAR-CCM+ Viewer is affected by a memory corruption vulnerability that could be triggered when the application reads scene (.sce) files. If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system. Siemens has released an update for Simcenter STAR-CCM+ Viewer and recommends to update to the latest version to fix the vulnerability. Siemens recommends to avoid opening of untrusted files from unknown sources. AFFECTED PRODUCTS AND SOLUTION ============================== * Simcenter STAR-CCM+ Viewer - Affected versions: All versions < V2022.1 - Remediation: Update to V2022.1 or later version See further recommendations from section "Workarounds and Mitigations" - Download: https://community.sw.siemens.com/s/article/Simcenter-STAR-CCM-Viewer-Download WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * Do not open untrusted scene files from unknown sources GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== Simcenter STAR-CCM+ Viewer is a light-weight, license-free standalone scene and plot viewer for Simcenter STAR-CCM+. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2022-24661 The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process. CVSS v3.1 Base Score: 7.8 CVSS Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CWE: CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer ACKNOWLEDGMENTS =============== Siemens thanks the following parties for their efforts: * Jin Huang from ADLab of Venustech for reporting the vulnerability ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2022-03-08): Publication Date TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmImnIAACgkQlm7gTEmy ujRKABAAwOQ992i35fOTYPDElFjYxo6rKFP05dQkge+DFyhWkwsYzZecjZ66WWIA FMYJZQ8KM2QtDJ3v+ua3NTmGUTuGWasttpA/MLlcCZqaWnVhp+gSGO0LbP5NvUHA 97Os/SBNTyxxIdxVFf5s4fLb2OQqdjrLRB3ULL+Wur9L4L4rGRRi64mhkrlR4IT+ hGPvjmSrzLG0rt//wVZm2+36Zn3PL1pnJoIvhCCLBE6JV9B7KnohdUFP92fcLwAM ZKBg4D+8VX1IQ4ixSX3QC9tPgw0JFFK07jS0VAgHEsi0myqjwUm1DwmKz2g2EklZ 3PmzlkecmQNWpnhUFP5e0h3sPmAStsKeDVDhUabUYzCQq6QgYYF3YeRwM7YXASZI 9dPIJzJBSEAFdDw2EiJivClIrV79iVJGRfwOd89jqn6woK5XZxw/fjTyd7jQWiRq yOz5YCjTPKHbHhCjsnJOO3n8INbRLLqJVGbi/Ek9P9XR2fTZq9TViBSofQUkDXBY R+z5Q1UPGZP43OHn7hCl6QOobA/15EuiwfGJJKha94/bTKt+ROov1Z6TKhn1ygMY Ghe4xZnBC/6XJvnzOMMKi/73B/lqKqIFoMHA8KVTUFh7JFmw3fiz8TJFuuTlvhBq ozFGfhYwiOYmpfy/CJN7YrxYVAweDWpydOa/pUF1AFn+UJ/wgmY= =qAz3 -----END PGP SIGNATURE-----