-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-474231: File Parsing Vulnerability in Simcenter Femap before V2022.2 Publication Date: 2022-07-12 Last Update: 2022-07-12 Current Version: 1.0 CVSS v3.1 Base Score: 7.8 SUMMARY ======= Siemens Simcenter Femap versions before V2022.2 are affected by an out of bounds write vulnerability that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released an update for the Simcenter Femap and recommends to update to the latest version. AFFECTED PRODUCTS AND SOLUTION ============================== * Simcenter Femap - Affected versions: All versions < V2022.2 - Remediation: Update to V2022.2 or later version See further recommendations from section "Workarounds and Mitigations" - Download: https://support.sw.siemens.com/ WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * Do not open untrusted X_T files in Simcenter Femap Product specific remediations or mitigations can be found in the section "Affected Products and Solution". Please follow the "General Security Recommendations". GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial- security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== Simcenter Femap is an advanced simulation application for creating, editing, and inspecting finite element models of complex products or systems. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2022-34748 The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17293) CVSS v3.1 Base Score: 7.8 CVSS Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CWE: CWE-787: Out-of-bounds Write ACKNOWLEDGMENTS =============== Siemens thanks the following parties for their efforts: * Trend Micro Zero Day Initiative for coordinated disclosure ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2022-07-12): Publication Date TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. Copyright: Siemens 2022 -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmLMuYAACgkQlm7gTEmy ujRQyBAAgZGcMBRfFqpvjpbVAdc9EF/KvJqRGAGJjAul0mmWMUP0cR4wJXrlAhmH AbDgePPXqAIbwWTqTd5plkn89Xh/+m4cNAUx7ldq5skeYs3YEAyS98GmdYRkWkqt 6YNj216u2KXP4+bbB7U9Btof2Gm67ZnuVAk8SQVBjCdgZ1qIYmnSy+yC/42QO5ME qddB8e79oYd19YDCdrZvtF49A+9Y7Lh5H3pmusD/f/0+qDo48sSlB930xuql2qGG pp9kTOdkOPW1yTBCt2gEBZlOiN1I0eT0airPAn6kCxrDS6oPbaZxPQYjFfM25IZJ qnXTGHqJsE/IlqaJpL+D3JmbYnqEe3FqeQseFevR1oUeqekFkXVWgRm+l3pgaoiK myeiQcyScM68LgJgHGK/Qwd0vWvACByrJquGUW4NbvwZ/5K7qKOKbzIJj7r+PT4W w9xW6ug5/E/90QDslT+hkX2p18sKFyxemHRhKCl4EWLl48PDNCMYEI3wYmSn9NJ0 vt6+fB0zCjpyHZUDh7b8Y2XdeG+xWWLRcq8ctZBXANaRO6cspK50tTBJqIzhmjEo uFBfxoO684ah//lhKG3SMx6M2TSsmKK1WNzUyn4sjP41Tg0v9KUC6p+Nj3p9TDOY qPJPEQwPuHxtTaPIEHEmcZvca601LBvUS24l33XTQ9ApqHAGqU0= =qKxP -----END PGP SIGNATURE-----