-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-534763: Special Register Buffer Data Sampling (SRBDS) aka Crosstalk in Industrial Products Publication Date: 2020-09-08 Last Update: 2022-03-08 Current Version: 1.6 CVSS v3.1 Base Score: 5.5 SUMMARY ======= Security researchers published information on a vulnerability known as Crosstalk (INTEL-SA-00320). This vulnerability affects modern Intel processors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerability. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. AFFECTED PRODUCTS AND SOLUTION ============================== * SIMATIC Field PG M4 - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC Field PG M5 - Affected versions: All BIOS versions < V22.01.08 - Remediation: Update BIOS to V22.01.08 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC Field PG M6 - Affected versions: All BIOS versions < V26.01.07 - Remediation: Update BIOS to V26.01.07 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC347E - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC427D (incl. SIPLUS variants) - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC427E (incl. SIPLUS variants) - Affected versions: All BIOS versions < V21.01.14 - Remediation: Update BIOS to V21.01.14 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC477D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC477E - Affected versions: All BIOS versions < V21.01.14 - Remediation: Update BIOS to V21.01.14 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC477E Pro - Affected versions: All BIOS versions < V21.01.14 - Remediation: Update BIOS to V21.01.14 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC527G - Affected versions: All BIOS versions < V1.4.0 - Remediation: Update BIOS to V1.4.0 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC547E - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC547G - Affected versions: All BIOS versions < R1.28.0 - Remediation: Update BIOS to R1.28.0 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC627D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC627E - Affected versions: All BIOS versions < V25.02.06 - Remediation: Update BIOS to V25.02.06 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC647D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC647E - Affected versions: All BIOS versions < V25.02.06 - Remediation: Update BIOS to V25.02.06 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC677D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC677E - Affected versions: All BIOS versions < V25.02.06 - Remediation: Update BIOS to V25.02.06 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC827D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC847D - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC IPC847E - Affected versions: All BIOS versions < V25.02.06 - Remediation: Update BIOS to V25.02.06 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMATIC IPC3000 SMART V2 - Affected versions: All versions < V1.B - Remediation: Update BIOS to V1.B or later version See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/cn/en/view/109763408/ * SIMATIC ITP1000 - Affected versions: All BIOS versions < V23.01.08 - Remediation: Update BIOS to V23.01.08 See further recommendations from section "Workarounds and Mitigations" - Download: https://support.industry.siemens.com/cs/ww/en/view/109763408 * SIMOTION P320-4E - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" * SIMOTION P320-4S - Affected versions: All versions - Remediation: Currently no remediation is planned See recommendations from section "Workarounds and Mitigations" WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * As a prerequisite for an attack, an attacker must be able to run untrusted code on affected systems. Siemens recommends limiting the possibilities to run untrusted code if possible. * Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== SIMATIC Field PG is a mobile, industry-standard programming device for automation engineers with all commonly used interfaces for industrial applications that also brings pre-installed SIMATIC engineering software. SIMATIC IPC (Industrial PC) is the hardware platform for PC-based automation from Siemens. SIMOTION is a scalable high performance hardware and software system for motion control. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the product they are based on. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2020-0543 Incomplete cleanup from specific special register read operations in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. CVSS v3.1 Base Score: 5.5 CVSS Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C CWE: CWE-200: Exposure of Sensitive Information to an Unauthorized Actor ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2020-09-08): Publication Date V1.1 (2020-10-13): Removed SINUMERIK 840D sl (NCU730.3B), SINUMERIK 828D (PPU.4 / PPU1740), and SINUMERIK ONE (NCU1750 / NCU1760) from the list of affected products. Added solution for SIMATIC IPC627E, SIMATIC IPC647E, SIMATIC IPC677E, and SIMATIC IPC847E V1.2 (2020-12-08): Added solution for SIMATIC IPC427E, SIMATIC IPC477E, and SIMATIC IPC477E PRO V1.3 (2021-02-09): Added solution for SIMATIC Field PG M5, and SIMATIC Field PG M6 V1.4 (2021-04-13): Added solution for SIMATIC ITP1000 and SIMATIC IPC547G V1.5 (2021-06-08): Added solution for SIMATIC IPC527G V1.6 (2022-03-08): Added solution for SIMATIC IPC3000 SMART V2 and clarified that no further fixes are planned TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmImnIAACgkQlm7gTEmy ujRQtg//VU98p11z9R11Q4n/IaXflzyvqvBD9+Nm1nITlNQXBCVdOPhNAEjfp3bW bdVVq5MKmrfGiFbQEo452VHWwUEZKFwMIwZh9XullyQiwljPBKIi1Ab3II7OfLGY Ylp8ES00qrKs9oMlQERcIBZF/qTROjuQ0znT6j8LkfEfbC5Pj6Kea3qsfaySwKP7 5kd6I7UGcb38MZJv1855O9iV7y8TXS0R/6EWKPfNVD4Uxqb/uiRr4we4nWas45Zl rKlZStJGYlQSPli/MqNpAfN94FPWPiN9RtFvKumi2l8fmdL4yg30HNTfv7jekIUT pHn7ZDAGV9sSgKmMit4Ek6MRzn5/SJdg6httKveER7NkwfImnpYRQ/ijSYQRwmuq DAZ+S4NE7ac5h+TF7fRS2VXrUCj4r2oYuN7d6k+4rhrvxqwy1qZxcy6KV8cbgWcE NvGa8TNwsE/z+fayrqoIQ1lBJ3qbjBijEIpHeDxEjH8KavMgtRrnU+RuNBEIPK2U hn2RQc84ZV/jvasWdxyXEhnNXnPc3MvLVMHqvE943IvgER/xxtKJBFw4ZaVDvfDl 3mV2dRdvind6Lj1YzHyE/dGbZVIWer2RDa+GBjD0/uZf1Ek1WzTAUV0tu9pBkmXD +35PBJIM1Qc2bwCO1YQ2TykW9dEtuAE/DN88IcR0K85JVS8Cpbg= =IgJG -----END PGP SIGNATURE-----