-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-560465: DHCP Client Vulnerability in VxWorks-based Industrial Products Publication Date: 2021-07-13 Last Update: 2022-05-10 Current Version: 1.2 CVSS v3.1 Base Score: 9.8 SUMMARY ======= Various industry products are affected by a DHCP client vulnerability in Wind River VxWorks, that could allow an attacker to cause a heap-based buffer overflow. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. AFFECTED PRODUCTS AND SOLUTION ============================== * RUGGEDCOM WIN5100 series subscriber unit - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * RUGGEDCOM WIN5200 series subscriber unit - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X201-3P IRT PRO (6GK5201-3BH00-2BD2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204-2 (6GK5204-2BB10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204-2FM (6GK5204-2BB11-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204-2LD (6GK5204-2BC10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204-2LD TS (6GK5204-2BC10-2CA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204-2TS (6GK5204-2BB10-2CA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204IRT (6GK5204-0BA00-2BA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X206-1 (6GK5206-1BB10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X206-1LD (6GK5206-1BC10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X208 (6GK5208-0BA10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X208PRO (6GK5208-0HA10-2AA6) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X212-2 (6GK5212-2BB00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X212-2LD (6GK5212-2BC00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X216 (6GK5216-0BA00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X224 (6GK5224-0BA00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (2x 24V) (6GK5302-7GD00-2EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (2x 24V, coated) (6GK5302-7GD00-2GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (2x 230V) (6GK5302-7GD00-4EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (2x 230V, coated) (6GK5302-7GD00-4GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (24V) (6GK5302-7GD00-1EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (24V, coated) (6GK5302-7GD00-1GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (230V) (6GK5302-7GD00-3EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X302-7 EEC (230V, coated) (6GK5302-7GD00-3GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X304-2FE (6GK5304-2BD00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (2x 24V) (6GK5307-2FD00-2EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (2x 24V, coated) (6GK5307-2FD00-2GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (2x 230V) (6GK5307-2FD00-4EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (2x 230V, coated) (6GK5307-2FD00-4GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (24V) (6GK5307-2FD00-1EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (24V, coated) (6GK5307-2FD00-1GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (230V) (6GK5307-2FD00-3EA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-2 EEC (230V, coated) (6GK5307-2FD00-3GA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-3 (6GK5307-3BL00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-3 (6GK5307-3BL10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-3LD (6GK5307-3BM00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X307-3LD (6GK5307-3BM10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2 (6GK5308-2FL00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2 (6GK5308-2FL10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LD (6GK5308-2FM00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LD (6GK5308-2FM10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LH (6GK5308-2FN00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LH (6GK5308-2FN10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LH+ (6GK5308-2FP00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2LH+ (6GK5308-2FP10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M (6GK5308-2GG00-2AA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M (6GK5308-2GG10-2AA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M PoE (6GK5308-2QG10-2AA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M TS (6GK5308-2GG00-2CA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X308-2M TS (6GK5308-2GG10-2CA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X310 (6GK5310-0FA00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X310 (6GK5310-0FA10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X310FE (6GK5310-0BA00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X310FE (6GK5310-0BA10-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE X408-2 (6GK5408-2FD00-2AA2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF201-3P IRT (6GK5201-3JR00-2BA6) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF204 (6GK5204-0BA00-2AF2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF204-2 (6GK5204-2BC00-2AF2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF204IRT (6GK5204-0BA00-2BF2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF206-1 (6GK5206-1BC00-2AF2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XF208 (6GK5208-0BA00-2AF2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG00-2ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 24V, ports on front) (6GK5324-4GG10-2ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG00-2JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 24V, ports on rear) (6GK5324-4GG10-2JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-4ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-4ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-4JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-4JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG00-1ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (24V, ports on front) (6GK5324-4GG10-1ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG00-1JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (24V, ports on rear) (6GK5324-4GG10-1JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG00-3ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) (6GK5324-4GG10-3ER2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG00-3JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) (6GK5324-4GG10-3JR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M PoE (24V, ports on front) (6GK5324-4QG00-1AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M PoE (24V, ports on rear) (6GK5324-4QG00-1HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M PoE (230V, ports on front) (6GK5324-4QG00-3AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M PoE (230V, ports on rear) (6GK5324-4QG00-3HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-4M PoE TS (24V, ports on front) (6GK5324-4QG00-1CR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG00-1AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (24V, ports on front) (6GK5324-0GG10-1AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG00-1HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (24V, ports on rear) (6GK5324-0GG10-1HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG00-3AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (230V, ports on front) (6GK5324-0GG10-3AR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG00-3HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M (230V, ports on rear) (6GK5324-0GG10-3HR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M TS (24V) (6GK5324-0GG00-1CR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SCALANCE XR324-12M TS (24V) (6GK5324-0GG10-1CR2) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC RF180C (6GT2002-0JD00) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC RF182C (6GT2002-0JD10) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SIMATIC RFID 181EIP (6GT2002-0JD20) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" * SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) - Affected versions: All versions - Remediation: Currently no fix is planned See recommendations from section "Workarounds and Mitigations" WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * Avoid the use of the DHCP client if unnecessary to your environment. * If the DHCP client is enabled, it is recommended to disable it. Please follow the "General Security Recommendations". GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== RUGGEDCOM WIN products are used as base stations or subscriber units in wide area private wireless networks. The products are compliant to the IEEE 802.16e standard and can be operated in harsh environments. SCALANCE X switches are used to connect industrial components like Programmable Logic Controllers (PLCs) or Human Machine Interfaces (HMIs). SIMATIC RF181EIP SIMATIC RF182C is an RFID communication module for direct connection of SIMATIC identification systems to Ethernet/IP. SIMATIC RF182C is superseded by the SIMATIC RF18xC devices (RF185C, RF186C, RF188C). SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the product they are based on. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2021-29998 There is a DHCP vulnerability in Wind River VxWorks, for versions prior to 6.5. The vulnerability could cause a possible heap overflow if exploited. CVSS v3.1 Base Score: 9.8 CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CWE: CWE-122: Heap-based Buffer Overflow ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2021-07-13): Publication Date V1.1 (2022-04-12): Clarified that no remediation is planned for some products; Clarified product names; Added SIMATIC RF180C; Added solution for SCALANCE X-300/X408 family V1.2 (2022-05-10): ERRATA: Removed solution for SCALANCE X-300/X408 family TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. Copyright: Siemens 2022 -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmJ5qwAACgkQlm7gTEmy ujQdrA/7B4uct11riG+8m0Ku506mr5ro7uJyIUB3M2Sc/3kVhONVXkOuDsXlhhhh J4bkbXSU1MRoEhHiqmLuY+tUQ5mk82P2svvJ8nwSA9+6vAnaT83rXTyB2YqqiI+1 TmeyrGaTnw9WJ+jEP2Cc5W8dvLg3++IDzHeB8FkYmN4KfsHN/k2VenSledKttvQf YM2E8OWZ+kvb92oPOcH+cHWum2vu6wCV5V7m4C9Ilv/Dby+WJP9RIcQLZtfGEGob VxnA6l9wh1Fhwp/BJhglFSh2GC/2YKywJJOTdQQOsXxySAWxmEJFxVQCPrzsvVdA Lt9ETAZIEKV51xDduU6Eiqi049bDi+qI24KvLaHxZj9FoKkrTmrVfL+VE27Si74g auw1WUBzkzYsfx66OMOAbRNNlEZHIOjy9V4aF6lk/U/J7ia1V+/QKYbBxa3qzZU8 RK0qMe/pIXoRuQ0abMeE/12JufhmquV9wUpdXW8N6rRU564U3m8VgX4ILjPWsHyM mQ/7Xvvi98z3BF1z8AN0B/ZxNtkDwirrVJi/v4yiIz+uCdDXbsLOiWgrna8iLilc HzjlxedqlkCZtF0ZphwWGfhGd2HeOr7VHmE43IjurX9bzjaNgSlyEtqYtvHGJpqf 3QJT5VzoogIQgpzv4yYQ2U2S7CYKEeHM3obn9P6UyCXIJ3p6MQU= =y2LA -----END PGP SIGNATURE-----