-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-831168: Cross-Site Scripting Vulnerability in Spectrum Power 4 Publication Date: 2022-02-08 Last Update: 2022-02-08 Current Version: 1.0 CVSS v3.1 Base Score: 5.4 SUMMARY ======= A Cross-Site Scripting (XSS) vulnerability is found in the integrated web application "Online Help" of Spectrum Power 4. Siemens has released an update for the Spectrum Power 4 and recommends to update to the latest version. AFFECTED PRODUCTS AND SOLUTION ============================== * Spectrum Power 4 - Affected versions: All versions < V4.70 SP9 Security Patch 1 - Remediation: Update to V4.70 SP9 Security Patch 1 or later version. Please contact your local Siemens representative. See further recommendations from section "Workarounds and Mitigations" WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * Do not open unknown links while working on Spectrum Power 4. GENERAL SECURITY RECOMMENDATIONS ================================ Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Digital Grid Products can be found at: https://www.siemens.com/gridsecurity PRODUCT DESCRIPTION =================== Spectrum Power provides basic components for SCADA, communications, and data modeling for control and monitoring systems. Application suites can be added to optimize network and generation management for all areas of energy management. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2022-23312 The integrated web application "Online Help" in affected product contains a Cross-Site Scripting (XSS) vulnerability that could be exploited if unsuspecting users are tricked into accessing a malicious link. CVSS v3.1 Base Score: 5.4 CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C CWE: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') ACKNOWLEDGMENTS =============== Siemens thanks the following parties for their efforts: * Jacinto Moral Matellán and Aarón Flecha Menéndez from S21Sec for reporting the vulnerability ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2022-02-08): Publication Date TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. -----BEGIN PGP SIGNATURE----- iQIzBAEBCgAdFiEEHyx/myPwjH9jB9tDlm7gTEmyujQFAmIBsoAACgkQlm7gTEmy ujTL1BAAyzojIzfJ88Umk2gf2oUgjolTrexhCOlFSYBglY+lctCRCw47n/kS0seU g3MnAm8NS/NmASvsQfHKeSO4J4zutRssM40RKt9hqnNol7yU5J2UCX/3VIQrmo+p W1jjB9WZV+Hwq2lJnrmrfEJQsRgU690fHfQ/IemFYm7TQdKm6xR0QNtd/CF3HN9V VpiAtdarjDUlOJ+/wQ7RXOowBg4cg6miY0Nq19vBeD1wUkJJkE8g8xlVtknFSavB op9nk5BwBYuqc76ZfTL+NtgRkPuB+KudlMN1iVO3+Lu5+gmopkIScY2PH9wotYHD JLnAPCG2+peQtN/Yyb2Y9jMWi4ZxU0TC0rfVYjgQ2uBcAVXxfiem2LrqTZBzpV8v I5fOOPWN9xtuuk82PX6OJ/fL1cAIJQqhUhf9K+mnTl6OpY21fI/Vf3ukC/AOmc1A FooJMjJZb2jNUhcxe3fOTFgTLUz80EFtOfqQriG9dDne+cuzl5ZnABA23xSrIrZV xqwcOvE0pAwlrIqIKIAlk7d9YNNSmGcB44LM8fssF4NqWJwNgtmJOSwAn0TgaFoY s6WJGIGLZ09Z9VESl+hSto2410/4HzP4goxe3Nix6MccrbJfVT0D7UkYmI5R9mCr jVX63eQyPTANVCdL3bOsDiA7/xLGFAyVSw3FpXRVT8JXsjUbXfc= =U+Jb -----END PGP SIGNATURE-----