-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 # SSA-874235: Intel Vulnerability in Siemens Industrial Products Publication Date: 2017-06-26 Last Update: 2020-02-10 Current Version: 1.4 CVSS v3.1 Base Score: 9.8 SUMMARY ======= Several Intel chipsets for Intel Core i5, Intel Core i7 and Intel XEON are susceptible to remote code execution vulnerability (CVE-2017-5689) [1]. As several Siemens Industrial Products use Intel technology, they are also affected. Siemens has released updates for the affected Industrial PCs. [1] Intel Security Advisory – INTEL-SA-00075:https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00075&languageid=en-fr AFFECTED PRODUCTS AND SOLUTION ============================== * Customized IPCs - Affected versions: Customized versions - Remediation: For those devices, customers will be informed directly by Siemens. * Field PG M3 - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * Field PG M4 - Affected versions: BIOS < V18.01.06 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * Field PG M5 - Affected versions: BIOS < V22.01.03 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * IPC627D / IPC677D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC427D - Affected versions: BIOS < V17.0?.10 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC427E - Affected versions: BIOS < V21.01.04 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC477D - Affected versions: BIOS < V17.0?.10 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC547D - Affected versions: ME < V7.1.91.3272 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC547E - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC547G - Affected versions: ME < V11.0.26.3000 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC627C / IPC677C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC647C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC647D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC847C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * PCS 7 IPC847D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC427D (incl. SIPLUS variants) - Affected versions: BIOS < V17.0?.10 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC427E (incl. SIPLUS variants) - Affected versions: BIOS < V21.01.05 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC477D - Affected versions: BIOS < V17.0?.10 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC477D PRO - Affected versions: BIOS < V17.0?.10 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC477E - Affected versions: BIOS < V21.01.05 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC547D - Affected versions: ME < V7.1.91.3272 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC547E - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC547G - Affected versions: ME < V11.0.26.3000 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC627C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC627D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC647C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC647D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC677C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC677D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC827C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC827D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC847C - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC IPC847D - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMATIC ITP1000 - Affected versions: ME < V9.1.41.3024 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SIMOTION P320-4 Standard - Affected versions: BIOS < S17.02.06.83.1 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 * SINUMERIK PCU50.5-P - Affected versions: ME < V6.2.61.3535 - Remediation: Update firmware - Download: https://support.industry.siemens.com/cs/ww/en/view/109747626 WORKAROUNDS AND MITIGATIONS =========================== Siemens has identified the following specific workarounds and mitigations that customers can apply to reduce the risk: * Apply the Defense-in-Depth concept:https://www.siemens.com/industrialsecurity GENERAL SECURITY RECOMMENDATIONS ================================ As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity PRODUCT DESCRIPTION =================== SIMATIC Industrial PCs are the PC hardware platform for PC-based Automation from Siemens. SIPLUS extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP, SINAMICS, SIMOTION, SCALANCE or other devices. SIPLUS devices use the same firmware as the product they are based on. SINUMERIK Panel Control Unit (PCU) offers HMI functionality for SINUMERIK CNC controllers. SIMOTION P320 is an Industrial PC for motion control. VULNERABILITY CLASSIFICATION ============================ The vulnerability classification has been performed by using the CVSS scoring system in version 3.1 (CVSS v3.1) (https://www.first.org/cvss/). The CVSS environmental score is specific to the customer's environment and will impact the overall CVSS score. The environmental score should therefore be individually defined by the customer to accomplish final scoring. An additional classification has been performed using the CWE classification, a community-developed list of common software security weaknesses. This serves as a common language and as a baseline for weakness identification, mitigation, and prevention efforts. A detailed list of CWE classes can be found at: https://cwe.mitre.org/. * Vulnerability CVE-2017-5689 Unprivileged local or remote attackers can gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM) and Intel Small Business Technology (SBT). CVSS v3.1 Base Score: 9.8 CVSS Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C CWE: CWE-264: Permissions, Privileges, and Access Controls ACKNOWLEDGMENTS =============== Siemens thanks the following parties for their efforts: * Artem Zinenko from Kaspersky for pointing out that SIPLUS should also be mentioned ADDITIONAL INFORMATION ====================== For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories HISTORY DATA ============ V1.0 (2017-06-26): Publication Date V1.1 (2017-06-29): Minor changes V1.2 (2017-07-06): Removed two SINUMERIK from affected products section, added new updates V1.3 (2017-07-13): Updates for all products available V1.4 (2020-02-10): SIPLUS devices now explicitly mentioned in the list of affected products TERMS OF USE ============ Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use. -----BEGIN PGP SIGNATURE----- iQIcBAEBCgAGBQJeQJ0AAAoJENP0geoRSq/kKk4QAMk16MpYTDt9D9gnAb9QOIIR udbqGLby1K/0XQevnTOrPw9Ihb6vaUayVnIgQeR+iYHVztqMILSFrSAkgmd+8kyG 17/p6pCutW9IdH4p1MR9SxbO0IPUly2ABNw2Hwkj+hGagesm7gu3P5BXDhupCtsS /Fgq9sA7yG4kdRAaNf4GLCuZWuaHTXDRaR6vHp6wRUK3VMdPH5U3CN0oZLRIciwr HqYzWzBja6KIy1H2vVTvC7X6yJlmyv7m6fU/5NTk8EvM8lZ42DzqyhPM89kALNKO 5VJ68SgQnFV+5aOtc5l0wgDMiwFLOJqI7Uo8UiYuQq5FX4OzWaO4ISH80H2C0R07 91KOdrrBaZh860BYfuz1BWpyFLvpbpNqjZwml2LrK24wZBB5Da8DCYOiKE3Zv/Do Mat6Kh6ehepxbr2cODzLVcVk/EFWzHmGKVg4fBSP8sfrrtVRB2q86wIJLHf6ieUj kgRPXAXTLgCf7p/aJG0RTAiwf8MEzpt989ZOJoIDO9nRZf+7DFMinG6RndFYKzIJ 5t9ju/rZP/5NhzGSfW38T3W6mGMca31fS/GdERMheAg0DPVMvrYD0g9q8qJiQ4HC 9P9U9Xtcq+Uq7tfN4AXx3GLLR0aByYj8JC/2gG4s9tMvQRHqtGJ5w+a+0Bb8H+oX JmfA0l8U4U/XxsewL2hd =y6Tn -----END PGP SIGNATURE-----